Skip to content

Finding 112

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.9 °C
Where
Table MODULES-0313, module 55
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 112
Thermal close-upColour range 37.8 °C to 43.1 °C
Photo of finding 112
PhotoFrom photo-027

Its modules

Table MODULES-0313: the filled module is module 55.

Close view
The whole table
Module 1, north endNorthModule 81, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0313 is filled black and ringed.

Open the plan

Details

Number
112
Class
Hotspot
Severity
None
Temperature difference
2.9 °CHottest point minus the module's mean
Maximum
43.1 °C
Mean
40.2 °C
Minimum
37.8 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0313
Modules
55/81 · 1 module
Demonstration position
40.56154196820945, -81.08687533735252Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-027
Photo cut from
photo-027
Thermal colour range
37.8 °C to 43.1 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026