Skip to content

Finding 123

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.7 °C
Where
Table MODULES-0158, module 2
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 123
Thermal close-upColour range 35.4 °C to 40.5 °C
Photo of finding 123
PhotoFrom photo-029

Its modules

Table MODULES-0158: the filled module is module 2.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0158 is filled black and ringed.

Open the plan

Details

Number
123
Class
Hotspot
Severity
None
Temperature difference
2.7 °CHottest point minus the module's mean
Maximum
40.5 °C
Mean
37.8 °C
Minimum
35.4 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0158
Modules
2/54 · 1 module
Demonstration position
40.56278402598842, -81.08680049181358Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-029
Photo cut from
photo-029
Thermal colour range
35.4 °C to 40.5 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026