Finding 125

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
3.5 °C
Where
Table MODULES-0062, module 29
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 125
Thermal close-upColour range 25.3 °C to 33.8 °C
Photo of finding 125
PhotoFrom photo-032

Its modules

Table MODULES-0062: the filled module is module 29.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0062 is filled black and ringed.

Open the plan

Details

Number
125
Class
Hotspot
Severity
None
Temperature difference
3.5 °CHottest point minus the module's mean
Maximum
33.8 °C
Mean
30.3 °C
Minimum
25.3 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0062
Modules
29/54 · 1 module
Demonstration position
40.563091111020576, -81.08679642064948Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-032
Photo cut from
photo-032
Thermal colour range
25.3 °C to 33.8 °C

Left and right arrow keys move to the previous and next finding.