Skip to content

Finding 129

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
4.5 °C
Where
Table MODULES-0056, module 29
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 129
Thermal close-upColour range 30.4 °C to 37.3 °C
Photo of finding 129
PhotoFrom photo-030

Its modules

Table MODULES-0056: the filled module is module 29.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0056 is filled black and ringed.

Open the plan

Details

Number
129
Class
Hotspot
Severity
None
Temperature difference
4.5 °CHottest point minus the module's mean
Maximum
37.3 °C
Mean
32.8 °C
Minimum
30.4 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0056
Modules
29/54 · 1 module
Demonstration position
40.563066379102416, -81.08691433882647Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-030
Photo cut from
photo-030
Thermal colour range
30.4 °C to 37.3 °C

Left and right arrow keys move to the previous and next finding.