Finding 145

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.6 °C
Where
Table MODULES-0164, module 2
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 145
Thermal close-upColour range 31.7 °C to 36.1 °C
Photo of finding 145
PhotoFrom photo-033

Its modules

Table MODULES-0164: the filled module is module 2.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0164 is filled black and ringed.

Open the plan

Details

Number
145
Class
Hotspot
Severity
None
Temperature difference
2.6 °CHottest point minus the module's mean
Maximum
36.1 °C
Mean
33.5 °C
Minimum
31.7 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0164
Modules
2/54 · 1 module
Demonstration position
40.56282107386562, -81.08662357006621Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-033
Photo cut from
photo-033
Thermal colour range
31.7 °C to 36.1 °C

Left and right arrow keys move to the previous and next finding.