Finding 149

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
3.8 °C
Where
Table MODULES-0170, module 28
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 149
Thermal close-upColour range 30.5 °C to 37.0 °C
Photo of finding 149
PhotoFrom photo-035

Its modules

Table MODULES-0170: the filled module is module 28.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0170 is filled black and ringed.

Open the plan

Details

Number
149
Class
Hotspot
Severity
None
Temperature difference
3.8 °CHottest point minus the module's mean
Maximum
37.0 °C
Mean
33.2 °C
Minimum
30.5 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0170
Modules
28/54 · 1 module
Demonstration position
40.562584178337715, -81.08645036520926Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-035
Photo cut from
photo-035
Thermal colour range
30.5 °C to 37.0 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026