Finding 154
?
Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.
Hotspot
None
Warm spot on the mounting structure
- Temperature difference
- 3.6 °C
- Where
- Table MODULES-0176, module 2
- Cause
- Mounting structure (suspected)
- Next step
- Field Check


Its modules
Table MODULES-0176: the filled module is module 2.
Module 1, north endNorthModule 54, south end
Filled black: the modules this finding covers. Outlined: the rest of the table.
On the plant
Details
- Number
- 154
- Class
- Hotspot
- Severity
- None
- Temperature difference
- 3.6 °CHottest point minus the module's mean
- Maximum
- 36.4 °C
- Mean
- 32.8 °C
- Minimum
- 28.3 °C
- Cause
- Mounting structure (suspected)
- Next step
- Field Check
- Table
- MODULES-0176
- Modules
- 2/54 · 1 module
- Demonstration position
- 40.56289516984859, -81.0862699925198Latitude and longitude after the plant was moved for this demonstration.
- Seen in
- 1 thermal frame
- Close-up cut from
- frame-037
- Photo cut from
- photo-037
- Thermal colour range
- 28.3 °C to 36.4 °C