Skip to content

Finding 34

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.5 °C
Where
Table MODULES-0270, module 55
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 34
Thermal close-upColour range 40.2 °C to 43.6 °C
Photo of finding 34
PhotoFrom photo-010

Its modules

Table MODULES-0270: the filled module is module 55.

Close view
The whole table
Module 1, north endNorthModule 81, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0270 is filled black and ringed.

Open the plan

Details

Number
34
Class
Hotspot
Severity
None
Temperature difference
2.5 °CHottest point minus the module's mean
Maximum
43.6 °C
Mean
41.1 °C
Minimum
40.2 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0270
Modules
55/81 · 1 module
Demonstration position
40.56133199850601, -81.08787733920255Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-010
Photo cut from
photo-010
Thermal colour range
40.2 °C to 43.6 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026