Finding 39
?
Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.
Hotspot
None
Warm spot on the mounting structure
- Temperature difference
- 3.4 °C
- Where
- Table MODULES-0008, module 1
- Cause
- Mounting structure (suspected)
- Next step
- Field Check


Its modules
Table MODULES-0008: the filled module is module 1.
Module 1, north endNorthModule 27, south end
Filled black: the modules this finding covers. Outlined: the rest of the table.
On the plant
Details
- Number
- 39
- Class
- Hotspot
- Severity
- None
- Temperature difference
- 3.4 °CHottest point minus the module's mean
- Maximum
- 40.0 °C
- Mean
- 36.6 °C
- Minimum
- 30.1 °C
- Cause
- Mounting structure (suspected)
- Next step
- Field Check
- Table
- MODULES-0008
- Modules
- 1/27 · 1 module
- Demonstration position
- 40.56352124214555, -81.08809308464704Latitude and longitude after the plant was moved for this demonstration.
- Seen in
- 1 thermal frame
- Close-up cut from
- frame-012
- Photo cut from
- photo-012
- Thermal colour range
- 30.1 °C to 40.0 °C
Left and right arrow keys move to the previous and next finding.