Skip to content

Finding 50

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
1.9 °C
Where
Table MODULES-0119, module 29
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 50
Thermal close-upColour range 40.3 °C to 44.6 °C
Photo of finding 50
PhotoFrom photo-014

Its modules

Table MODULES-0119: the filled module is module 29.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0119 is filled black and ringed.

Open the plan

Details

Number
50
Class
Hotspot
Severity
None
Temperature difference
1.9 °CHottest point minus the module's mean
Maximum
44.6 °C
Mean
42.7 °C
Minimum
40.3 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0119
Modules
29/54 · 1 module
Demonstration position
40.56228979970098, -81.08780620664771Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-014
Photo cut from
photo-014
Thermal colour range
40.3 °C to 44.6 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026