Skip to content

Finding 59

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.3 °C
Where
Table MODULES-0284, module 29
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 59
Thermal close-upColour range 42.2 °C to 45.5 °C
Photo of finding 59
PhotoFrom photo-017

Its modules

Table MODULES-0284: the filled module is module 29.

Close view
The whole table
Module 1, north endNorthModule 81, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0284 is filled black and ringed.

Open the plan

Details

Number
59
Class
Hotspot
Severity
None
Temperature difference
2.3 °CHottest point minus the module's mean
Maximum
45.5 °C
Mean
43.2 °C
Minimum
42.2 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0284
Modules
29/81 · 1 module
Demonstration position
40.561680136995086, -81.08752012953431Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-017
Photo cut from
photo-017
Thermal colour range
42.2 °C to 45.5 °C

Left and right arrow keys move to the previous and next finding.