Finding 73
?
Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.
Hotspot
None
Warm spot on the mounting structure
- Temperature difference
- 2.4 °C
- Where
- Table MODULES-0131, module 29
- Cause
- Mounting structure (suspected)
- Next step
- Field Check


Its modules
Table MODULES-0131: the filled module is module 29.
Module 1, north endNorthModule 54, south end
Filled black: the modules this finding covers. Outlined: the rest of the table.
On the plant
Details
- Number
- 73
- Class
- Hotspot
- Severity
- None
- Temperature difference
- 2.4 °CHottest point minus the module's mean
- Maximum
- 42.5 °C
- Mean
- 40.1 °C
- Minimum
- 38.9 °C
- Cause
- Mounting structure (suspected)
- Next step
- Field Check
- Table
- MODULES-0131
- Modules
- 29/54 · 1 module
- Demonstration position
- 40.56233916292846, -81.0875703693561Latitude and longitude after the plant was moved for this demonstration.
- Seen in
- 1 thermal frame
- Close-up cut from
- frame-019
- Photo cut from
- photo-019
- Thermal colour range
- 38.9 °C to 42.5 °C