Skip to content

Finding 95

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
4.4 °C
Where
Table MODULES-0144, module 27
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 95
Thermal close-upColour range 30.8 °C to 39.5 °C
Photo of finding 95
PhotoFrom photo-023

Its modules

Table MODULES-0144: the filled module is module 27.

Close view
The whole table
Module 1, north endNorthModule 54, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0144 is filled black and ringed.

Open the plan

Details

Number
95
Class
Hotspot
Severity
None
Temperature difference
4.4 °CHottest point minus the module's mean
Maximum
39.5 °C
Mean
35.1 °C
Minimum
30.8 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0144
Modules
27/54 · 1 module
Demonstration position
40.562438489723704, -81.08721643671265Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-023
Photo cut from
photo-023
Thermal colour range
30.8 °C to 39.5 °C

Left and right arrow keys move to the previous and next finding.