Skip to content

Finding 158

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.8 °C
Where
Table MODULES-0049, module 55
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 158
Thermal close-upColour range 28.9 °C to 34.4 °C
Photo of finding 158
PhotoFrom photo-038

Its modules

Table MODULES-0049: the filled module is module 55.

Close view
The whole table
Module 1, north endNorthModule 81, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0049 is filled black and ringed.

Open the plan

Details

Number
158
Class
Hotspot
Severity
None
Temperature difference
2.8 °CHottest point minus the module's mean
Maximum
34.4 °C
Mean
31.6 °C
Minimum
28.9 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0049
Modules
55/81 · 1 module
Demonstration position
40.56320075246698, -81.08632474835474Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-038
Photo cut from
photo-038
Thermal colour range
28.9 °C to 34.4 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026