Skip to content

Finding 159

?

Heat from a table's mounting structure, not from a module: listed and drawn, never counted as a defect.

Hotspot

None

Warm spot on the mounting structure

Temperature difference
2.7 °C
Where
Table MODULES-0044, module 28
Cause
Mounting structure (suspected)
Next step
Field Check
Thermal close-up of finding 159
Thermal close-upColour range 28.1 °C to 32.6 °C
Photo of finding 159
PhotoFrom photo-039

Its modules

Table MODULES-0044: the filled module is module 28.

Close view
The whole table
Module 1, north endNorthModule 81, south end

Filled black: the modules this finding covers. Outlined: the rest of the table.

On the plant

Table MODULES-0044 is filled black and ringed.

Open the plan

Details

Number
159
Class
Hotspot
Severity
None
Temperature difference
2.7 °CHottest point minus the module's mean
Maximum
32.6 °C
Mean
29.9 °C
Minimum
28.1 °C
Cause
Mounting structure (suspected)
Next step
Field Check
Table
MODULES-0044
Modules
28/81 · 1 module
Demonstration position
40.56344806099741, -81.08649786444641Latitude and longitude after the plant was moved for this demonstration.
Seen in
1 thermal frame
Close-up cut from
frame-039
Photo cut from
photo-039
Thermal colour range
28.1 °C to 32.6 °C

Left and right arrow keys move to the previous and next finding.

Lumerian Labs 2026